Eurorack Reference / modules /alm-busy-circuits/quaid-megaslope audit site v0.1 — milestone 3
alm-busy-circuits/quaid-megaslope

Quaid Megaslope

ALM Busy Circuits

Five stage function generator or modulator which operates in one of 3 modes: a multistage 'CZ' or 'Juno' style complex envelope, a super flexible LFO, and a step sequencer with per step programmable slew or slides. Each mode produces a varying output voltage moving from point to point across a set number of chained together stages.381

Capabilities 3

Envelope Generatorenvelope-generator
Five-stage envelope with per-stage level, time, and slope control; gate input sustains at selected stage.381
LFOlfo
In Loop mode, automatically cycles across set stages creating a programmable LFO with variable stage levels and slopes.381
Step Sequencerstep-sequencer
In Step mode, trig advances stages with per-step programmable slew/slide via the Time control.381

Jacks 7 — 4 in / 3 out

NameSignalVoltageDescription
Inputs (4)
GategateIn Env mode, sustains the envelope at the selected stage level while high. In Step mode, resets the sequence to the first stage.381
Level CVcv0V to 5VPer stage voltage control of level. Values set by controls are added to this input value.381
Time CVcv0V to 5VPer stage voltage control of time. Values set by controls are added to this input value.381
TrigtriggerIn Env mode triggers a single cycle of all 5 stages. In Step mode, steps the sequencer to the next stage.381
Outputs (3)
+/-Outcv-5V to 5VBipolar output approximately -5V to +5V. When not active, sits at approximately -5V.381
+Outcv0V to 8VMain unipolar output, approximately 0–8V.381
EOCtriggerEnd of cycle output — emits a trigger when a full cycle is completed.381

Parameters 4

NameTypeRangeBehavior
LevelknobSets the final output voltage destination for the stage.381
ModebuttonSwitches the current operating mode between Step, Envelope, and Loop.381
SlopeknobVaries the slope type of the output path from logarithmic to linear to exponential.381
Timeknob≤180000msSets the time the stage takes to reach the destination level. Ranges from ~1-2ms (fully CCW) to ~3 minutes (fully CW), with 100ms at noon and 3 seconds around 9 o'clock.381

Firmware history 0 versions