Eurorack Reference / modules /doepfer/a-183-2 audit site v0.1 — milestone 3
doepfer/a-183-2

A-183-2 Offset-Generator / Attenuator / Polarizer

Doepfer

Voltage offset generator combined with an attenuator/polarizer. A toggle switch selects between attenuator and polarizer (attenuverter) modes. The DC offset is adjustable via the Offset knob, and the input signal can be attenuated or bipolar-scaled and added to the offset voltage.531

Capabilities 4

Attenuatorattenuator
In Attenuator mode (Att. switch position), the lower knob scales the input from 0 (fully CCW) to full level (fully CW), with gain range 0 to +1.531
Attenuverterattenuverter
In Polarizer mode (Pol. switch position), the lower knob acts as an attenuverter with gain range -1 to +1. Center is zero; CW adds non-inverted input; CCW adds inverted input.531
Offset Generatoroffset-generator
The Offset knob generates a DC voltage in a jumper-selectable range of 0..+5V or -5V..+5V, which is summed with the attenuated/polarized input signal at the output.531
Polarizerpolarizer
Polarizer mode allows the input signal to be attenuated and phase-inverted. The knob's center gives zero output; the polarity flips across the center position.531

Jacks 2 — 1 in / 1 out

NameSignalVoltageDescription
Inputs (1)
Incv531
Outputs (1)
OutcvTwo physically connected output sockets presenting the same voltage — acts as a passive multiple. Outputs the sum of the DC offset voltage and the attenuated/polarized input signal.531

Parameters 4

NameTypeRangeBehavior
Att./Pol. KnobknobIn Attenuator mode, scales the input signal from 0 (fully CCW) to maximum (fully CW). In Polarizer mode, center position gives zero output; right of center adds the input signal; left of center subtracts (inverts) the input signal. The distance from center defines the intensity.531
Zones
attenuator
Zero
  • Zero -100–-100%Fully CCW: zero level (no input signal passed).531
polarizer
Subtracts (Inverted)
Adds (Non-inverted)
  • Subtracts (Inverted) -100–0%Left of center: the In signal is subtracted from (inverted relative to) the offset voltage. At fully CCW, the inverted input is added at maximum level.531
  • Adds (Non-inverted) 0–100%Right of center: the In signal is added to the offset voltage. At fully CW, the non-inverted input is added at maximum level.531
Mode SwitchswitchToggle switch that selects between Attenuator mode (Att.) and Polarizer mode (Pol.). Determines whether the lower knob acts as a standard attenuator (0 to +1 gain) or a polarizer/attenuverter (-1 to +1 gain).531
OffsetknobSets the DC offset voltage at the output. Range is jumper-selectable between 0..+5V or -5V..+5V. This offset is summed with the attenuated/polarized input signal.531
Offset Range JumperjumperSelects the voltage range of the Offset knob. Upper jumper position: 0..+5V. Lower jumper position: -5V..+5V.531

Firmware history 0 versions

No firmware history recorded.

References 1

  1. [531]
    Doepfer A-183-2 Offset-Generator / Attenuator / Polarizer product pageproduct_page
    verified 2026-05-19