doepfer/a-183-2
A-183-2 Offset-Generator / Attenuator / Polarizer
Voltage offset generator combined with an attenuator/polarizer. A toggle switch selects between attenuator and polarizer (attenuverter) modes. The DC offset is adjustable via the Offset knob, and the input signal can be attenuated or bipolar-scaled and added to the offset voltage.531
Capabilities 4
- Attenuatorattenuator
- In Attenuator mode (Att. switch position), the lower knob scales the input from 0 (fully CCW) to full level (fully CW), with gain range 0 to +1.531
- Attenuverterattenuverter
- In Polarizer mode (Pol. switch position), the lower knob acts as an attenuverter with gain range -1 to +1. Center is zero; CW adds non-inverted input; CCW adds inverted input.531
- Offset Generatoroffset-generator
- The Offset knob generates a DC voltage in a jumper-selectable range of 0..+5V or -5V..+5V, which is summed with the attenuated/polarized input signal at the output.531
- Polarizerpolarizer
- Polarizer mode allows the input signal to be attenuated and phase-inverted. The knob's center gives zero output; the polarity flips across the center position.531
Jacks 2 — 1 in / 1 out
| Name | Signal | Voltage | Description |
|---|---|---|---|
| Inputs (1) | |||
| In | cv | — | 531 |
| Outputs (1) | |||
| Out | cv | — | Two physically connected output sockets presenting the same voltage — acts as a passive multiple. Outputs the sum of the DC offset voltage and the attenuated/polarized input signal.531 |
Parameters 4
| Name | Type | Range | Behavior |
|---|---|---|---|
| Att./Pol. Knob | knob | — | In Attenuator mode, scales the input signal from 0 (fully CCW) to maximum (fully CW). In Polarizer mode, center position gives zero output; right of center adds the input signal; left of center subtracts (inverts) the input signal. The distance from center defines the intensity.531 Zones attenuator
polarizer
|
| Mode Switch | switch | — | Toggle switch that selects between Attenuator mode (Att.) and Polarizer mode (Pol.). Determines whether the lower knob acts as a standard attenuator (0 to +1 gain) or a polarizer/attenuverter (-1 to +1 gain).531 |
| Offset | knob | — | Sets the DC offset voltage at the output. Range is jumper-selectable between 0..+5V or -5V..+5V. This offset is summed with the attenuated/polarized input signal.531 |
| Offset Range Jumper | jumper | — | Selects the voltage range of the Offset knob. Upper jumper position: 0..+5V. Lower jumper position: -5V..+5V.531 |
Firmware history 0 versions