Eurorack Reference / modules /make-noise/optomix audit site v0.1 — milestone 3
make-noise/optomix

Optomix

Make Noise

Two-channel Low Pass Gate using 4 vactrols for simultaneous voltage control over amplitude and frequency content, with DAMP, STRIKE, summing stage, and AUX input.401

Capabilities 6

Compressorcompressor
Sidechain compression via audio-rate DAMP input; compression ratio set by CONTROL Combo Pot.401
Envelope Generatorenvelope-generator
STRIKE input with DAMP parameter allows percussive envelope generation without a dedicated envelope generator.401
Low Pass Gatelow-pass-gate
Two-channel vactrol-based LPG providing simultaneous voltage control over amplitude and frequency content.401
Mixermixer
Summing stage with AUX input for chaining multiple units to create larger mixes.401
Vcfvcf
Mild, non-resonant lowpass filter that simultaneously attenuates amplitude and high frequency content.401
Voltage-Controlled Amplifiervca
Acts as a VCA with moderate attack and slow decay, producing organic, ringing response.401

Jacks 11 — 8 in / 3 out

NameSignalVoltageDescription
Inputs (8)
AUX INmixed≤10VDirect-coupled input to the SUM circuit for chaining multiple Optomix or modDemix units into larger mixes.401
CH1 CONTROL INcv401
CH1 DAMP CV INmixed0V to 8VCV input for channel 1 DAMP parameter, normalized to +8V. Accepts audio or CV.401
CH1 STRIKE INgate≤8V401
CH2 CONTROL INcv401
CH2 DAMP CV INmixed0V to 8V401
CH2 STRIKE INgate≤8V401
CH2 Signal INmixed≤10V401
Outputs (3)
CH1 Signal OUTmixed≤10V401
CH2 Signal OUTmixed≤10V401
SUM OUTmixed≤10VSum/mix output of all signals processed by the Optomix.401

Parameters 4

NameTypeRangeBehavior
CH1 CONTROL Combo PotknobUnipolar attenuator for CH1 CONTROL signal input. When nothing is patched, operates as a level control for the internal offset.401
CH1 DAMP Combo PotknobUnipolar attenuator for CH1 DAMP CV input. When nothing is patched to DAMP CV IN, operates as a direct manual control for the DAMP parameter.401
CH2 CONTROL Combo PotknobUnipolar attenuator for CH2 CONTROL signal input. When nothing is patched, operates as a level control for the internal offset.401
CH2 DAMP Combo PotknobUnipolar attenuator for CH2 DAMP CV input. When nothing is patched to DAMP CV IN, operates as a direct manual control for the DAMP parameter.401

Firmware history 0 versions

No firmware history recorded.

References 2

  1. [401]
    Optomix Manualmanual
    verified 2026-05-15
  2. [402]
    Make Noise Optomix product pageproduct_page
    ⚠ verified 2026-05-15 · manufacturer changed since last verified